Cabinet: All corrosion-resistant stainless steel type-316L, inside and outside including interior shelves, mountings and drip basin.  Satin finish on all exterior surfaces for an attractive and easily-cleaned lustrous appearance.  Bottle-support ring made of durable and corrosion-resistant polypropylene.

Controls: protected from environment by installation inside NEMA 4 enclosure. 

Valves: Self-closing, no-drip cup filler. Made from durable and corrosion-resistant polypropylene.

Cold Water Reservoir: Flat-bottom stainless steel basin with approximately 2-1/2 quarts (2.4 liters) useable capacity and polypropylene fittings.  Corrosion-protected copper evaporator coil is wrapped around reservoir, insulated with closed-cell elastomer. 

Corrosion Protection: Capillary tube, sight glass, filter-dryer, two access valves and all metal tubing protected with either a special epoxy coating (e-coat) with near-zero porosity applied electrostatically and then baked or with Dupont Corlar enamel to protect them from acidic and caustic corrosion. 

Condenser: Triple layer, sized for high ambient temperatures and high altitudes, and protected against acidic and other corrosion with a special epoxy coating (e-coat) with near-zero porosity applied electrostatically and oven cured.

Compressor:  Andover Protection Systems’ Model EEG (for 115/60/1) or APS Model EEJ (220-240/50-60/1).  These compressors are specifically designed for and recognized by UL (Underwriters Laboratories) for use in hazardous conditions as well as being especially resistant to corrosion.

Refrigerant:  Environmentally-friendly HFC R134-a as approved by Montreal Protocol.

Capacity:

Rated Capacity: At water and air temperature of 131º F (55ºC)— lower 1/2 gallon per hour of water from 131ºF (55ºC) to 50ºF (10ºC) –Note:  131ºF water will scald skin; therefore, chiller must lower the water 81ºF (27ºC) degrees to reach the standard chilled-water temperature of 50ºF (10ºC).

Capacity at ARI (Air-Conditioning and Refrigeration Institute) standard conditions: water and air temperature of 90ºF (32.2ºC)—lower 0.9  gallons per hour of water from 90ºF (32.2ºC) to 50ºF (10ºC) -- (50% more cold water than standard units)

ADA:  Overall, the coolers comply with the requirements of the ADA (Americans with Disabilities Act) specification 4.15.2-4

Shipping Specifications: Approximately 73 lbs. and 8.6 cubic feet.

Hazardous-Duty:  When specified, DMC makes the units suitable for hazardous-duty conditions, even those requiring explosion-proof or flame-proof equipment.  It will use UL-recognized hazardous-duty compressors appropriate for the classification of the area.  DMC offers bottled-water coolers suitable for use in areas classified in any of the following ways:  (Classes I, II, III, Groups B, C, D, E, F, and G, Divisions/Zones 1 and 2 and IEC Classes I, IIA, IIB, and IIB+Hydrogen, Zones 1 and 2)  The units will be factory sealed for fast and easy installation.  The hazardous-duty units will have all the standard harsh-duty features of DMC's standard coolers.